SDIO

From Wiki :-)
Revision as of 17:04, 24 June 2020 by Savoundg (talk | contribs)
Jump to navigation Jump to search

Commands Table

CMD Index Argument Response Abbreviation Command Description
CMD18 [31:0] data address R1 READ_MULTIPLE_BLOCK Continuously transfers data blocks from card to host until interrupted by a STOP_TRANSMISSION command.

Responses

R1

Bit position 47 46 [45:40] [39:8] [7:1] 0
Width (bits) 1 1 6 32 7 1
Value '0' '0' x x x '1'
Description start bit transmission bit command index card status CRC7 end bit

References

SD Specifications Part E1 SDIO Simplified Specification http://academy.cba.mit.edu/classes/networking_communications/SD/SD.pdf